A control system for a three phase active power filter which simultaneously compensates power factor and unbalanced loads

机译:三相有源电力滤波器的控制系统,可同时补偿功率因数和不平衡负载

获取原文

摘要

The effectiveness of an active power filter depends basically on three characteristics: (a) the modulation method used, (b) the design characteristics of the PWM modulator and (c) the method implemented to generate the reference template. For the last characteristic there are many methods, most of them complicated and hence difficult to implement and adjust. In this paper, a new method, which its main characteristic is its simplicity, is presented. This method is useful for shunt active power filters and is capable to eliminate harmonics, compensate power factor and correct unbalance problems simultaneously. Experimental results, with the reference template obtained with the method, are presented in the paper.
机译:有效功率滤波器的有效性基本上取决于三个特性:(a)使用的调制方法,(b)PWM调制器的设计特性和(c)实现以生成参考模板的方法。对于最后一个特征,有许多方法,其中大多数复杂,因此难以实现和调整。本文介绍了一种新方法,其主要特征是其简单性。该方法对于分流有源电力滤波器很有用,并且能够消除谐波,补偿功率因数并同时正确的不平衡问题。实验结果,用该方法获得的参考模板,本文提出。