Partial discharge (PD) measurements performed on different high-voltage apparatus using a computer-controlled phase resolving PD analyzer (PRPDA) are described. The PRPDA system records the PD activity of a test object during a given number of cycles of the applied AC voltage or during a fixed time. Some typical results obtained in SF/sub 6/-insulated systems gas-insulated systems, power transformers, and power generators in offline and in online conditions are presented and discussed. An advantage of the PRPDA measuring system is the possibility of performing a statistical analysis of the PD data.
机译:描述了使用计算机控制的相分辨PD分析仪(PRPDA)在不同的高压设备上进行的局部放电(PD)测量。 PRPDA系统在给定的交流电压循环次数或固定时间内记录测试对象的PD活动。提出并讨论了在SF / sub 6 /绝缘系统,气体绝缘系统,电力变压器和发电机离线和在线条件下获得的一些典型结果。 PRPDA测量系统的优点是可以对PD数据进行统计分析。