首页> 外文会议>Instrumentation and Measurement Technology Conference, 1989. IMTC-89. Conference Record., 6th IEEE >Application of a new radiation thermometry method to galvannealed and cold-rolled steels
【24h】

Application of a new radiation thermometry method to galvannealed and cold-rolled steels

机译:一种新的辐射测温方法在镀锌和冷轧钢中的应用

获取原文

摘要

The authors describe an experimental and analytical study of a novel radiation thermometry method. The method uses a priori knowledge concerning the reciprocal relationship between two uniquely defined spectral emissivities, making quite accurate temperature measurement possible for materials to which conventional spectral and ratio methods are not applicable. The validity of the method is demonstrated by experimental results on galvannealed and cold-rolled steel specimens, whose emissivity changes by alloying and oxidation, respectively. Zinc film thickness, steel grade, and alloying temperature had little effect on the reciprocity function for the two emissivities. It is concluded that the use of two polarized spectral emissivities at the same wavelength can be advantageous in measuring the temperature and emissivities of cold-rolled steel in a continuous annealing furnace.
机译:作者描述了一种新型辐射测温方法的实验和分析研究。该方法利用了关于两个唯一定义的光谱发射率之间的倒数关系的先验知识,从而使得对于不适用常规光谱和比率方法的材料进行非常精确的温度测量成为可能。通过对镀锌和冷轧钢试样的实验结果证明了该方法的有效性,它们的发射率分别随合金化和氧化而变化。锌膜厚度,钢种和合金化温度对两种发射率的互易函数影响很小。可以得出结论,使用相同波长的两个偏振光谱发射率在连续退火炉中测量冷轧钢的温度和发射率时可能是有利的。