Models have been presented to describe the discharge processes which occur when a steep-front, intense voltage pulse is injected onto an open wire transmission line in air. Measurements made to evaluate these models are reported. The experimental data include transient voltage and current on the open wire, photographs of the discharge which forms at the wire and between the wire and ground, and maps of the transient electric field at the ground plane. Variables include voltage, length and size of the wire, height of the wire above the ground plane and duration of the voltage pulse. These data provide an empirical model for the pulsed corona, since V-I behavior under a range of conditions is presented in convenient graphical form. In addition, several characteristics included in theoretical models are examined in terms of the data. The importance of the diffuse corona (glow) component in supporting the voltage at the wire is evaluated. Ground field mapping is shown to be a useful diagnostic tool.
机译:已经提出了模型来描述放电过程,该放电过程是在空气中将陡峭的前部强电压脉冲注入到裸线传输线上时发生的。报告了为评估这些模型而进行的测量。实验数据包括裸线上的瞬态电压和电流,在电线上以及在电线与地面之间形成的放电照片,以及在接地层的瞬态电场图。变量包括电压,导线的长度和尺寸,导线在接地平面上方的高度以及电压脉冲的持续时间。这些数据为脉冲电晕提供了经验模型,因为在一系列条件下的V-I行为以方便的图形形式表示。此外,还根据数据检查了理论模型中包含的几个特征。评估了扩散电晕(辉光)分量在支撑导线电压时的重要性。地面场测绘被证明是一种有用的诊断工具。