This paper introduces an advanced monitoring and diagnosis technique for the detection of incipient stator electrical faults in doubly-fed induction generators (DFIG) used in wind turbines. Thanks to the measurability of DFIG rotor side electrical characteristics, a new diagnostic method based on the frequency analysis of rotor instantaneous power spectrum is proposed. Theoretical analysis shows that, compared with the common current or voltage spectrum analysis methods, the instantaneous power spectrum also has the advantage that external sensors and hardware devices are not needed. Moreover, its characteristic frequency is 2f without slip s (f is the fundamental frequency), so this method has its unique advantage which has good interference immunity to avoid the mis-diagnosis. Once some slip tracking or calculation errors occurred, the characteristic frequency would not change.
机译:本文介绍了一种先进的监测和诊断技术,用于检测风力涡轮机中使用的双馈感应发电机(DFIG)中的初始定子电气故障。由于DFIG转子侧电气特性的可测量性,提出了一种基于转子瞬时功率谱频率分析的新诊断方法。理论分析表明,与常用的电流或电压谱分析方法相比,瞬时功率谱还具有不需要外部传感器和硬件设备的优点。此外,其特征频率为2f,无滑动s(f为基频),因此该方法具有其独特的优势,即具有良好的抗干扰性,可以避免误诊。一旦发生一些滑动跟踪或计算错误,特征频率就不会改变。