Displacement ventilation, as a dedicated outdoor air system, to satisfy demand of comfort degree in work area, supplies low temperature and low speed fresh air, formed 'air lake' near floor surface. Due to the influence of heat source, supply air is heated and goes arise, and reduces the surface temperature of heating object, with air outlet discharged exhausted air as much as possible. Radiant cooling is a type of air condition system which is run by exchanging heat between radiant panel and room air, with low temperature, realized high energy efficiency ratio of unit. According to statistics, radiant cooling air condition system can save about 28--40% energy compared with conventional system. Based on national meteorological parameters, C.Stetin carried out simulation calculation on commercial buildings and found that energy consumption of radiant cooling system could save as much as 30%. In conclusion, floor radiant cooling with displacement ventilation system is a new technology to which is paid much attention recently. Based on the method of computational fluid dynamics (CFD), indoor thermal environment of an laboratory was studied by numerical simulation of hybrid air-conditioning system of displacement ventilation and chilled panel with two load conditions/. The results indicate that the new system can reduce indoor temperature gradient and improve human thermal comfort.
机译:作为专用户外空气系统,满足工作区舒适度的需求,提供低温和低速新鲜空气,在地板上形成“空气湖”。由于热源的影响,供应空气被加热并出现,并降低加热物体的表面温度,并且尽可能地排出排出的空气排出排出的空气。辐射冷却是一种空气调节系统,通过在辐射板和室内空气之间的热量之间进行热量,具有低温,实现的单元的高能效率。根据统计,与传统系统相比,辐射冷却空气状态系统可以节省约28-40%的能量。基于国家气象参数,C.Stetin对商业建筑进行了仿真计算,发现辐射冷却系统的能耗可以节省多达30%。总之,具有位移通风系统的地板辐射冷却是一种新技术,最近得到了很多关注。基于计算流体动力学(CFD)的方法,通过具有两个负载条件的流动通风和冷却面板的混合空调系统的数值模拟研究了实验室的室内热环境。结果表明,新系统可以降低室内温度梯度,提高人类热舒适度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号