Introduction: Our primary goal was to evaluate the performance of a new high-efficiency electric fence energizer unit using resistive load changes. Our secondary goal was to test for compliance with the classical energy limits and the newer charge-based limits for output. Methods: We tested 4 units of the Nemtek Druid energizer with 2 channels each. We used a wide load-resistance range to cover the worst-case scenario of a barefoot child making a chest contact (400 Ω) up to an adult merely touching the fence (2 kΩ). Results: The energy output was quite consistent between the 8 sources. Even at the lowest resistance, 400 Ω, the outputs were well below the IEC 60335-2-76 limit of 5 J/pulse. The charge delivered was also quite consistent. Even at the lowest resistance, 400 Ω, the outputs (679 ± 23 µC) were well below the proposed limits of 4 mC for short pulses. Conclusions: The high-efficiency electric fence energizers satisfied all relevant safety limits. Charge, energy, voltage, and current outputs were consistent between channels and units.
机译:简介:我们的主要目标是使用电阻性负载变化来评估新型高效电围栏激励器单元的性能。我们的次要目标是测试是否符合经典的能量限制和更新的基于电荷的输出限制。方法:我们测试了4个带有2个通道的Nemtek Druid激励器。我们使用了很宽的负载电阻范围,以覆盖赤脚儿童仅接触栅栏(2kΩ)直至成年人接触胸部(400Ω)的最坏情况。结果:8个源之间的能量输出相当一致。即使在最低电阻400Ω时,输出也远远低于IEC 60335-2-76 5 J /脉冲的极限。交付的费用也相当一致。即使在最低电阻400Ω时,输出(679±23 µC)仍远低于建议的短脉冲4 mC限制。结论:高效电围栏激励器满足所有相关的安全限制。通道和单元之间的电荷,能量,电压和电流输出保持一致。