首页> 外文会议>ITG/GMM Symposium >Automatic Initial Sizing of Operational Amplifiers with Support of Weak, Moderate and Strong Inversion
【24h】

Automatic Initial Sizing of Operational Amplifiers with Support of Weak, Moderate and Strong Inversion

机译:运算放大器的自动初始大小调整,支持弱,中度和强反转

获取原文

摘要

This paper presents a method to automatically size op-amps using simple transistor models. A constraint program based on analytical formulas is used to initially size the op-amps which emulates the manual analog design process. While analytical equations are used to model the transistors in weak and strong inversion, the gm/Id-method based on look-up tables is used for the transistor model in moderate inversion. Experimental results are presented for an op-amp with transistors in the three inversion regions.
机译:本文提出了一种使用简单晶体管模型自动调整运算放大器尺寸的方法。使用基于解析公式的约束程序来初步模拟运算放大器的大小,以模拟手动模拟设计过程。虽然分析方程式用于在弱反演和强反演中对晶体管建模,但是基于查找表的gm / Id方法用于中等反演中的晶体管模型。给出了在三个反相区域中具有晶体管的运算放大器的实验结果。