首页> 外文会议>European Conference on Power Electronics and Applications >Validity of power cycling lifetime models for modules and extension to low temperature swings
【24h】

Validity of power cycling lifetime models for modules and extension to low temperature swings

机译:功率循环寿命模型对模块的有效性以及对低温摆幅的扩展

获取原文

摘要

Various papers in power electronics contain a part of lifetime estimation depending on power cycles in application. The used model is often the CIPS08 lifetime model published at the conference CIPS 2008. In many applications, a lot of cycles with low temperature swings occur. The used model, however, is only valid for temperature swings above 40 K. For temperature swings < 30 K, there are strong deviations, since some materials are now approaching the elastic region. First experimental power cycling results are gained below 30 K temperature swing. Also an approximation for the reliability of low temperature swing is given in this paper.
机译:电力电子学中的各种论文都包含寿命估算的一部分,具体取决于应用中的电源循环。使用的模型通常是在CIPS 2008大会上发布的CIPS08寿命模型。在许多应用中,会发生许多具有低温摆幅的循环。但是,所使用的模型仅对40 K以上的温度波动有效。对于<30 K的温度波动,由于某些材料正在接近弹性区域,因此存在很大的偏差。在低于30 K的温度摆幅下获得了第一个实验功率循环结果。本文还给出了低温摆幅可靠性的近似值。