Vortex flowmeter was firstly applied in industry control in late 1960s and widely used to take place of traditional flowmeters very soon. Considering the fact that research on large diameter vortex flowmeter is far behind requirement of industrial application, the author has proposed to conduct simulation on triangular column vortex 350mm diameter flowmeter based on the computational fluid dynamics theory. In flow field simulation water and air as transmitting medium has been analyzed and compared in affection of frequency and signal measurement. To determine the optimal pressure tapping position of 350mm diameter vortex flowmeter, check points have been set in various positions to obtain data of signal strength and signal to noise ratio under different flowing velocity. The results have proved that the optimal pressure tapping position should be 1.0 times of cut-off face from the vortex generating body.
机译:漩涡流量计首先在20世纪60年代后期应用于行业控制,并广泛地习惯了很快地发生传统流量计。考虑到大直径涡流流量计的研究落后于工业应用的要求,提议基于计算流体动力学理论对三角柱涡流350mm直径流量计进行仿真。在流场模拟中,在频率和信号测量的影响中分析并比较了透射介质的水和空气。为了确定直径350mm直径的最佳压力点击位置,在各种位置设置了检查点以在不同流动速度下获得信号强度和信噪比的数据。结果证明,最佳压力攻丝位置应为来自涡流产生体的截止面的1.0倍。