Study on optimal pressure tapping position of large diameter vortex flowmeter

机译:大直径涡街流量计的最佳放压位置研究

获取原文

摘要

Vortex flowmeter was firstly applied in industry control in late 1960s and widely used to take place of traditional flowmeters very soon. Considering the fact that research on large diameter vortex flowmeter is far behind requirement of industrial application, the author has proposed to conduct simulation on triangular column vortex 350mm diameter flowmeter based on the computational fluid dynamics theory. In flow field simulation water and air as transmitting medium has been analyzed and compared in affection of frequency and signal measurement. To determine the optimal pressure tapping position of 350mm diameter vortex flowmeter, check points have been set in various positions to obtain data of signal strength and signal to noise ratio under different flowing velocity. The results have proved that the optimal pressure tapping position should be 1.0 times of cut-off face from the vortex generating body.
机译:涡街流量计于1960年代末首次应用于工业控制领域,并很快被广泛用于取代传统流量计。考虑到大直径涡街流量计的研究远远落后于工业应用的要求,笔者提出了基于计算流体力学理论对350mm直径的三角柱涡街流量计进行仿真。在流场模拟中,对作为传输介质的水和空气进行了分析,并比较了频率和信号测量的影响。为了确定直径为350mm的涡街流量计的最佳分接位置,已在各个位置设置了检查点,以获得在不同流速下的信号强度和信噪比数据。结果证明,最佳的压力引出位置应为从涡流产生体切出的切面的1.0倍。