To investigate how PDs influenced by the oil flow speed and temperature in transformer oil, experiments with different PD defect models were carried out and parameters were recorded. Test results shown that the PD properties have significant relevance with the oil flow speed and oil temperature. At a certain temperature, the partial discharge voltage (PDIV) would increase while the maximum PD charges exhibits a fall trend as the oil flow speed increases. However, it would be different once the oil flow speed keeps unchangeable but the oil temperature varies. The PDIV presented an increase trend when the oil temperature was lower than 70°C, but decreases hereafter. Test results presented in this paper would be helpful for transformer operation condition optimization and thus to prolong the service life of its main insulation.
机译:为了研究变压器油中的油流速和温度的PDS如何影响,进行了不同PD缺陷模型的实验,并记录参数。测试结果表明,PD特性与油流速和油温具有显着相关性。在一定温度下,局部放电电压(PDIV)将增加,而当油流速增加时,最大PD电荷表现出跌倒趋势。然而,一旦油流速保持不变,而且油温变化会不同。当油温低于70°C时,PDIV提高了趋势,但下面减少。本文提出的测试结果对变压器操作条件优化有所帮助,从而延长其主要绝缘的使用寿命。