This paper proposes a unique coordinated ride-through capability enhancement scheme for Type IV wind generators to counter the impact of symmetrical and asymmetrical voltage swells. A novel protection hardware configuration is utilized to restrict the dc-link overvoltage and undervoltage in the event of voltage swells at the Point of Common Coupling (PCC), which would otherwise damage the converter. Moreover, a reactive power flow management algorithm is implemented to support the grid voltage during the transient event. A supervisory controller is used to control the insertion of the protection hardware and also to regulate the reactive power flow between the generator and grid. It is observed that there is substantial improvement in ride-through performance. A 10-MW Wound Rotor Synchrnous Generator (WRSG) wind farm in MATLAB/Simscape Power Systems is utilized to validate the effectiveness of the scheme. The 10 MW wind farm consists of 5 × 2-MW wind generators.
机译:本文提出了一种独特的协调乘坐能力增强方案,适用于IV型风力发电机,以对称和不对称电压膨胀的影响。一种新颖的保护硬件配置用于限制DC链路过电压和欠压,在通用耦合(PCC)的电压膨胀时,否则会损坏转换器。此外,实现了无功功率流量管理算法以在瞬态事件期间支持网格电压。监控控制器用于控制保护硬件的插入,并调节发电机和网格之间的无功功率流动。观察到,通过性能大大提高。 Matlab / Simscape Power系统中的10 MW缠绕转子同步发电机(WRSG)风电场用于验证该方案的有效性。 10兆瓦风电场由5×2-MW风力发电机组成。