In this paper, two passive solutions for noise reduction of PWM-fed induction machines are compared: the use of LC filter connected between the PWM inverter and the machine, and a three-phase damper wound inside the machine and connected to three capacitors. Firstly, the advantages and disadvantages of each solution are recalled. Then, the efficiency of both solutions in terms of harmonic flux density reduction is discussed. The weight and size criteria are also studied. Results are given for two different power range of induction machines: 4kW and 55kW.
机译:在本文中,比较了两种用于降低PWM馈电感应电机噪声的无源解决方案:在PWM逆变器和电机之间使用LC滤波器,以及在电机内部缠绕并连接至三个电容器的三相阻尼器。首先,回顾每种解决方案的优缺点。然后,讨论了两种解决方案在降低谐波通量密度方面的效率。还研究了重量和尺寸标准。给出了感应电机的两种不同功率范围的结果:4kW和55kW。