摘要

Currently, the evaluation methods of fiber insulation degradation state of power transformer are mostly based on accelerated thermal aging test in laboratory, and this paper is based on the evaluation of furfural content in 35kV field transformer oil. First, samples of the field transformer insulating oil are collected. Then, the insulating oil sample is subjected to an extraction experiment, and the furfural in the insulating oil is extracted by methanol solution. Next, the furfural standard solution is prepared, the methanol extract of the insulating oil and the standard solution are centrifuged and oscillated respectively. After filtration, it is placed in a high-performance liquid chromatograph (HPLC) for injection and measurement. Finally, the furfural content in the insulating oil is obtained. A quantitative equation between furfural and DP is used to evaluate the degree of polymerization (DP) of transformer insulation paper. Combined the field operation with maintenance data, the aging condition of the insulating paper is comprehensively evaluated, and the experimental evaluation results are verified, which provides a reliable reference for the safety operation of field transformers.
机译:目前,电力变压器纤维绝缘老化状态的评估方法主要是基于实验室加速热老化试验,本文基于对35kV现场变压器油中糠醛含量的评估。首先,收集现场变压器绝缘油的样品。然后,对绝缘油样品进行萃取实验,并用甲醇溶液萃取绝缘油中的糠醛。接下来,制备糠醛标准溶液,将绝缘油的甲醇提取物和标准溶液分别离心和振荡。过滤后,将其置于高效液相色谱仪(HPLC)中进行进样和测量。最后,获得了绝缘油中的糠醛含量。糠醛和DP之间的定量方程用于评估变压器绝缘纸的聚合度(DP)。结合现场运行与维护数据,对绝缘纸的老化状况进行了综合评估,并验证了实验评估结果,为现场变压器的安全运行提供了可靠的参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号