首页> 外文会议>IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference >Field No-load Test and the Uncertainty Calculation of No-load Loss Measurement Uncertainty for UHV Disintegration Transformer
【24h】

Field No-load Test and the Uncertainty Calculation of No-load Loss Measurement Uncertainty for UHV Disintegration Transformer

机译:特高压瓦解变压器的现场空载试验和空载损耗测量不确定度的不确定度计算

获取原文

摘要

The application of UHV disintegration transformer effectively solves the difficult problem of the construction of UHV power transmission and transformation project in remote areas. In order to verify the quality of the disassembly, transportation and assembly of the UHV transformer, to ensure safe and stable operation of UHV power grid, it is necessary to carry out no-load test at the site of UHV disintegration transformer. The principle of no-load test is described and the parameters of no-load test are calculated, the feasibility of no-load test at the site is demonstrated and the parameters of no-load test equipment selection and design ensure the on-site no-load test carried out smoothly. Finally, the uncertainty analysis of on-site no-load test is analyzed and calculated, the result shows that the designed no-load test equipment can meet the requirements of no-load test.
机译:特高压瓦解变压器的应用,有效解决了边远地区特高压输变电工程建设的难题。为了验证特高压变压器的拆卸,运输和组装的质量,为确保特高压电网的安全稳定运行,有必要在特高压瓦解变压器现场进行空载试验。描述了空载试验的原理,计算了空载试验的参数,论证了现场空载试验的可行性,并通过空载试验设备的选择和设计参数确保了现场无空载。负荷试验顺利进行。最后,对现场空载测试的不确定性分析进行了分析和计算,结果表明所设计的空载测试设备可以满足空载测试的要求。