Due to increase in power demand, over exploitation of existing power system causing huge burden on the network interms of voltage instability, more power losses in the network and power quality issues. In this paper the multiple DG placement and sizing is used to give potential solution for power loss minimizations with good profile within the acceptable voltage limits. The fuzzy logic technique is used for placement of DG and same is tested on s IEEE 33 bus system. The results obtained from fuzzy are satisfactory for stable operation of power system network.
机译:由于电力需求的增加,对现有电力系统的过度开发在电压不稳定,网络中更多的电力损耗以及电力质量问题方面给网络造成了巨大的负担。在本文中,使用多个DG放置和大小调整为潜在的解决方案提供了可能的解决方案,以在可接受的电压范围内以良好的轮廓实现功耗最小化。模糊逻辑技术用于DG的放置,并且已在s IEEE 33总线系统上进行了测试。从模糊获得的结果对于电力系统网络的稳定运行是令人满意的。