摘要

Preliminary data has shown that TOC and NDMA removal were dependent on temperature and possibly other factors such as ozone dose and presence of pre-oxidants like chlorine in the process. Since nitrification is most sensitive to these factors, it might prove to be an indicator of stress in the system and can be used a monitoring tool. Further studies are being carried out at lower temperatures and varying ozone doses to better determine the impact of temperature, ozone dose and chlorine on TOC and TrOC removal.
机译:初步数据表明,TOC和NDMA的去除取决于温度,还可能取决于其他因素,例如臭氧剂量和过程中氯等预氧化剂的存在。由于硝化对这些因素最敏感,因此它可能被证明是系统压力的指标,可以用作监视工具。在更低的温度和变化的臭氧剂量下正在进行进一步的研究,以便更好地确定温度,臭氧剂量和氯气对TOC和TrOC去除的影响。