首页> 外文会议>International Conference on Electrical Materials and Power Equipment >Signal Calibration for electric field measurement by the thermal pulse method
【24h】

Signal Calibration for electric field measurement by the thermal pulse method

机译:热脉冲法测定电场测量的信号校准

获取原文

摘要

Frequency response calibration is necessary in thermal pulse data processing. The study found that the thermal pulse data involves a larger frequency bandwidth. When the film sample is equivalent to a capacitor, the mutual coupling of the equivalent RLC components in the test circuit together determines the frequency response of the test system. Therefore, only using the frequency response of the amplifier will not be able to effectively calibrate the test data. This article proposes a method of full-field calibration, and it has been verified through experimental examples, which has achieved relatively good results.
机译:热脉冲数据处理需要频率响应校准。 研究发现,热脉冲数据涉及更大的频率带宽。 当胶片样本等同于电容器时,测试电路中的等效RLC组件的相互耦合将在一起确定测试系统的频率响应。 因此,仅使用放大器的频率响应将无法有效地校准测试数据。 本文提出了一种全场校准方法,通过实验例进行了验证,该实验示例已经取得了相对良好的效果。