首页> 外文会议>European rotorcraft forum >STUDIES ON THE INFLUENCE OF ROTOR DISTANCE ON THE EFFICIENCY OF A COAXIAL ROTOR SYSTEM
【24h】

STUDIES ON THE INFLUENCE OF ROTOR DISTANCE ON THE EFFICIENCY OF A COAXIAL ROTOR SYSTEM

机译:转子距离对同轴转子系统效率影响的研究

获取原文

摘要

Coaxial rotor systems are of special interest on aircraft with electric propulsion. An experimental analysis of the performance of such a system is described in this paper. Two rotors with identical geometry are operated at an equal rotational speed. The presented test bench allows to measure electrical and force data individually for both rotors. Analyses are conducted in the hover case as well as in a case with an axial incidence flow in a wind tunnel for various rotor separation distances. Efficiency of the rotor system is compared to a single rotor. It is shown that the separation distance of the rotors has a strong influence on the upper and lower rotor individually, although the combined performance is approximately independent in the hover case. In the case with an axial incidence flow, overall efficiency of the analyzed rotor system increases for a smaller rotor separation distance.
机译:同轴转子系统在带有电动推进器的飞机上特别受关注。本文描述了这种系统性能的实验分析。具有相同几何形状的两个转子以相同的转速运行。所提供的测试台允许分别测量两个转子的电气和力数据。对于不同的转子分离距离,在悬停情况下以及在风洞中有轴向入射流的情况下进行分析。将转子系统的效率与单个转子进行比较。可以看出,转子的分离距离对上,下转子都有很大的影响,尽管在悬停情况下综合性能几乎是独立的。在具有轴向入射流的情况下,对于较小的转子分离距离,所分析的转子系统的整体效率会提高。