The aim of voltage profile sag estimation (VPSE) is to reconstruct the voltage profile at non-monitored buses using measurements only from monitored buses. This paper compares two methods for voltage profile estimation: one which focuses on fault localization and another which reconstructs profiles using voltage thresholds. The two algorithms are compared using a generic 295 bus generic distribution network and 4 sets of monitoring locations. The 4 monitoring locations are selected using a bespoke artificial immune system optimization algorithm. The results of the two methods are compared by analyzing the distribution of error between the two methods and the estimated generalized sag tables of both algorithms. Preliminary results suggest that the two methods are very comparable in performance. Both algorithms are shown to be sensitive to the selected monitoring locations, and perform well even when the number of monitors is much less than the number of buses.
机译:电压分布SAG估计(VPSE)的目的是使用仅来自受监控总线的测量来重建非监控总线的电压分布。本文比较了两种电压分布估计方法:专注于故障定位的方法,以及使用电压阈值来重建曲线的另一个方法。使用通用295总线通用分配网络和4套监视位置进行比较这两种算法。使用定制人工免疫系统优化算法选择4个监测位置。通过分析两种方法之间的误差和两个算法的估计的广义下滑表之间的误差分布来进行比较这两种方法的结果。初步结果表明,两种方法在性能方面非常比较。两个算法都显示对所选的监视位置敏感,即使监视器的数量小于总线的数量,也表现良好。