This paper deals with ventilation - thermal calculation of the medium sized turbo generator with the output power 40 MW. The temperature and airflow were calculated using “Ansys Fluent”, The described work follows up on the ventilation calculation done in past. In particular, there are several options tested to figure out the behavior of the numerical model. The ventilation part of the numerical model was tuned according to analytical calculations, so it should be trustworthy. The individual options are characterized as reduction or addition of the flow cross section (flow inlet to transfer ducts, air gap inlet). The results show advantages and disadvantages of those options, also show the way how to improve the cooling compartment system of a turbo generator.
机译:本文研究了输出功率为40 MW的中型涡轮发电机的通风-热力计算。使用“ Ansys Fluent”计算温度和气流。所描述的工作是对过去进行的通风计算的跟进。特别是,有几种测试选项可以弄清楚数值模型的行为。数值模型的通风部分已根据分析计算进行了调整,因此应该值得信赖。各个选项的特征是减小或增加了流量横截面(到输送管道的流量入口,气隙入口)。结果显示了这些选择的优缺点,也显示了如何改善涡轮发电机的冷却室系统的方法。