Analysis of a Grid-Connected Shoot-Through Current Immune Three-Phase Converter Topoloy under Unbalanced Loading Conditions

机译:不平衡负载条件下并网直通电流免疫三相换流器拓扑结构分析

获取原文

摘要

The analysis of a shoot-through-proof converter topology designed to eliminate the need for a dead time between switching transitions is presented. Shoot-through-proof is done by splitting each leg of a normal converter and inserting an inductor to limit the current during transitions. Matlab/Simulink™ simulations based on a 10-kVA laboratory test setup, which was built to validate the proposed ideas, are used to evaluate the system performance. In particular, simulations were used to predict losses associated with the topology and reduce the harmonics injected by the converter. The control system was implemented in a TMS320F28335 DSP, and the results of both the simulations and prototype testing showed very good agreement.
机译:提出了一种旨在防止开关转换之间的空载时间需求的防直通转换器拓扑的分析。通过直通转换器的每一分支并插入电感器以限制过渡期间的电流,来实现直通测试。基于10 kVA实验室测试设置的Matlab / Simulink™仿真用于评估所提出的想法,用于评估系统性能。特别是,仿真被用来预测与拓扑相关的损耗并减少转换器注入的谐波。该控制系统在TMS320F28335 DSP中实现,仿真和原型测试的结果都显示出很好的一致性。