首页> 外文会议>IEEE Conference on Energy Internet and Energy System Integration >Stability Analysis and Control of Two-Stage Three-Phase Photovoltaic Grid-Connected System with Phase-Locked Loop
【24h】

Stability Analysis and Control of Two-Stage Three-Phase Photovoltaic Grid-Connected System with Phase-Locked Loop

机译:带锁相环的两阶段三相光伏并网系统的稳定性分析与控制

获取原文

摘要

This paper presents a small-signal model of two-stage three-phase photovoltaic grid-connected system including phase-locked loop (PLL). Using the eigenvalue analysis, the dominant oscillation mode of the system under weak grid conditions is determined and the results show that MPPT control parameters have relatively little impact on system stability. Based on the interaction between PLL and inner current loop, an additional control method is proposed to suppress the dominant oscillation mode. It is further proved by eigenvalue analysis and time domain simulation that the proposed method is correct. Then the lower limit values of the additional control coefficient under different PLL gains are given.
机译:本文提出了一个包含锁相环(PLL)的两阶段三相光伏并网系统的小信号模型。通过特征值分析,确定了弱电网条件下系统的主导振荡模式,结果表明MPPT控制参数对系统稳定性的影响相对较小。基于锁相环和内部电流环路之间的相互作用,提出了一种抑制主振荡模式的附加控制方法。通过特征值分析和时域仿真进一步证明了该方法的正确性。然后给出了不同PLL增益下附加控制系数的下限值。