首页> 外文会议>International Universities Power Engineering Conference >Dissolved gas analysis (DGA) and fourier transform infra red (FTIR) spectroscopy of thermal-aged natural ester-paper composite
【24h】

Dissolved gas analysis (DGA) and fourier transform infra red (FTIR) spectroscopy of thermal-aged natural ester-paper composite

机译:热老化的天然酯-纸复合材料的溶解气体分析(DGA)和傅里叶变换红外(FTIR)光谱

获取原文

摘要

Due to environmental consideration, natural ester was developed as liquid insulation for high voltage transformer. This paper reports the Dissolved gas Analysis (DGA) and Fourier Transform Infrareed (FTIR) Spectroscopy of Thermally-Aged Natural Ester-paper composite. The sample used were natural ester from palm oil and kraft paper insulation. The samples used in these experiments were natural ester from palm oil and kraft paper transformer insulation. The 200 gr of ester samples, 10 gr of kraft insulation paper, and 17.5 gr copper were put together with copper conductor in heat-resistant hermetic bottles to simulate actual condition of transformator. The samples were subjected to a thermal stress in a controllable oven at temperature of 120°C and 150°C. The thermal aging was conducted for duration of 2 weeks, 4 weeks and 6 weeks. The dissolved gas in the ester after a certain aging temperature and period was determined using a DGA testing. The gas species and the concentration of each gas under various aging conditions were analyzed. Dissolved gas analysis indicated that thermal aging in ester-paper composite insulation released, CH4 (Methane), C2H6 (ethane), and CO (Carbon Monoxide). FTIR measurement was conducted for the thermally-aged ester insulation. The comparative analysis of DGA and FTIR results was done to clarify the origin of the gas released in the thermally-aged ester paper composite insulation.
机译:出于环保考虑,天然酯被开发为高压变压器的液体绝缘材料。本文报道了热老化的天然酯-纸复合材料的溶解气体分析(DGA)和傅里叶变换红外(FTIR)光谱。所使用的样品是来自棕榈油和牛皮纸绝缘材料的天然酯。这些实验中使用的样品是棕榈油和牛皮纸变压器绝缘的天然酯。将200克酯样品,10克牛皮纸绝缘纸和17.5克铜与铜导体一起放入耐热的密封瓶中,以模拟变压器的实际情况。样品在可控制的烘箱中于120℃和150℃的温度下经受热应力。进行热老化2周,4周和6周。使用DGA测试确定在一定的老化温度和时间后,酯中的溶解气体。分析了各种老化条件下的气体种类和每种气体的浓度。溶解气体分析表明,酯纸复合绝缘材料的热老化释放出CH 4 (甲烷),C 2 H 6 (乙烷),和CO(一氧化碳)。对热老化的酯绝缘层进行了FTIR测量。对DGA和FTIR结果进行了比较分析,以弄清在热老化酯纸复合绝缘材料中释放的气体的来源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有