Mechanism of long-standing question of 300 to 400 degree Celsius hydrogen peak in steel measured by Thermal Desorption Spectroscopy and its extended concept

机译:热解吸光谱法测定钢中300至400摄氏度氢峰的长期问题机理及扩展概念

获取原文

摘要

This poster presentation reports on mechanism and extended concept about the phenomenon to appear hydrogen peak at around 300 to 400 °C region in Thermal Desorption Spectroscopy (TDS). Phenomenon to appear long-disputed hydrogen peak at around 300 to 400 °C in TDS: When hydrogen content is measured in TDS, hydrogen peak at around 300 to 400 °C often appears in rust-removed steel sample of intentionally-corroded steel samples, for example, by wet-and-dry cyclic corrosion test, or by exposing atmospheric condition near seashore. The hydrogen peak at around 300 to 400 °C does not appears in cathodically-charged steel sample. The origin of such hydrogen peak has been a long-disputed question at issue.
机译:该海报展示报告了在热脱附光谱法(TDS)中在300至400°C附近出现氢峰的现象的机理和扩展概念。在TDS中,在300至400°C左右会出现长时间争议的氢峰现象:在TDS中测量氢含量时,故意腐蚀的钢样品中除锈的钢样品中通常会在300至400°C处出现氢峰,例如,通过干湿循环腐蚀测试,或通过暴露在海边附近的大气条件。带有阴极电荷的钢样品中不会出现300至400°C左右的氢峰。这种氢峰的起源一直是一个备受争议的问题。