首页> 外文会议>International symposium on medical information processing and analysis >Automatic Detection of Perturbed Magnetic Resonance Signal
【24h】

Automatic Detection of Perturbed Magnetic Resonance Signal

机译:自动检测扰动的磁共振信号

获取原文

摘要

Magnetic resonance imaging (MRI) is widely used in medicine nowadays, yet a significant disadvantage is the amount of artifacts that affect the image during the acquisition process. This paper presents a strategy for automatic damage detection when the image is altered by movement or there is a loss of information due to magnetic susceptibility. This approach uses a conventional SVD to detect the variability between slices of the image and a region of damaged voxels within the volume. Using a simple derivative algorithm, the method was tested in several cases automatically revealing the distortion's location with a performance of 74% for slice damage and 55% for the volume's damaged region.
机译:如今,磁共振成像(MRI)已在医学中广泛使用,但是一个重大的缺点是在采集过程中会影响图像的伪影数量。本文提出了一种在图像因运动而改变或由于磁化率而导致信息丢失时自动检测损坏的策略。这种方法使用常规的SVD来检测图像切片与体积内受损体素区域之间的差异。使用一种简单的导数算法,在几种情况下对该方法进行了测试,以自动揭示变形的位置,切片损坏的性能为74%,体积损坏区域的性能为55%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号