摘要

The use of multilevel converters has been a trend in back-to-back converters employed in type-3 turbines based on doubly-fed induction generator (DFIG). In this sense, this work aims to compare the performance of three-phase converters of three-levels flying capacitor topology of two branches (FC-2B) and three branches (FC-3B). These structures are used like grid-side converter (GSC) with the capability to provide ancillary services on harmonic compensation and reactive power support. This study uses simulation results via PSCAD/EMTDC software. As a preliminary stage for future experimental trials, this work demonstrates that FC-2B is as efficient as FC-3B.
机译:在基于双馈感应发电机(DFIG)的3型涡轮机中使用的背靠背转换器中,多电平转换器的使用已成为一种趋势。从这个意义上讲,这项工作的目的是比较两个分支(FC-2B)和三个分支(FC-3B)的三级快速电容器拓扑的三相转换器的性能。这些结构的使用类似于电网侧变流器(GSC),具有在谐波补偿和无功功率支持方面提供辅助服务的能力。本研究使用通过PSCAD / EMTDC软件的仿真结果。作为未来实验试验的初步阶段,这项工作证明FC-2B与FC-3B一样有效。