首页> 外文会议>International Conference on Photonics Solutions >Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector
【24h】

Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector

机译:LC / UPC连接器的PANDA PMF的偏振消光比的合格测量设置

获取原文
获取外文期刊封面目录资料

摘要

Polarization Extinction Ratio (PER) is one of the key parameters for Polarization Maintaining Fiber (PMF) connector. Based on our previous studies, the bending radius of fiber greater than 1.5 cm will not affect the insertion loss of PMF [1]. Moreover, the measured PER of Panda PMF with LC/UPC connectors is more stable when that PMF is coiled around a hot rod with a minimum of 3-cm in diameter at 75°C temperature [2]. Hence, the hot rod with less constrained 6-cm in diameter at constant 75°C was selected for this PER measurement. Two PER setups were verified and compared for measuring LC/UPC PMF connectors. The Polarized Laser Source (PLS) at 1550 nm wavelength and PER meter from OZ Optics were used in both setups, in which the measured connector was connected to PLS at 0° angle while the other end was connected to PER meter. In order to qualify our setups, the percentage of Repeatability and Reproducibility (%R&R) were tested and calculated. In each setup, the PER measurement was repeated 3 trials by 3 appraisers using 10 LC/UPC PMF connectors (5 LC/UPC PMF patchcords with 3.5+0.5 meters in length) in random order. The 1~(st) setup, PMF was coiled at a larger 20-cm diameter for 3 to 5 loops and left in room temperature during the test. The 2~(nd) setup, PMF was coiled around a hot rod at constant 75°C with 6-cm diameter for 8 to 10 loops for at least 5 minutes before testing. There are 3 ranges of %R&R acceptation guide line: <10% is acceptable, between 10% - 30% is marginal, and >30% is unacceptable. According to our results, the %R&R of the 1~(st) PER test setup was 16.2% as marginality, and the 2~(nd) PER test setup was 8.9% as acceptance. Thus, providing the better repeatability and reproducibility, this 2~(nd) PER test setup having PMF coiled around a hot rod at constant 75°C with 6-cm diameter was selected for our next study of the impact of hot temperature on PER in LC/UPC PMF connector.
机译:偏振消光比(PER)是偏振保持光纤(PMF)连接器的关键参数之一。基于我们之前的研究,弯曲半径大于1.5cm的纤维不会影响PMF的插入损耗[1]。此外,当PMF在75℃温度下,熊猫PMF具有LC / UPC连接器的PANDA PMF的测量,当PMF围绕热棒绕着热棒时,在75℃的温度下最小3厘米[2]。因此,每次测量选择恒定75℃下直径较少约束6-cm的热棒。每个设置的两个都被验证并进行了测量LC / UPC PMF连接器。两个设置中使用了1550nm波长和每米的偏振光激光源(PL),在两个设置中使用,其中测量的连接器以0°角连接到PLS,而另一端连接到每米。为了有资格认证我们的设置,测试并计算重复性和重复性(%R&R)的百分比。在每个设置中,使用10 LC / UPC PMF连接器(5 LC / UPC PMF PatchCords以随机顺序重复每次测量3次试验。 1〜(ST)设置,PMF在直径较大的20厘米直径为3至5环,并在测试期间留在室温下。 2〜(Nd)设置,PMF在恒定的75℃下在热棒周围盘绕,6厘米直径为8至10个环,在测试前至少5分钟。有3个范围的%R&R接受指导线:<10%是可接受的,10% - 30%之间是边缘的,> 30%是不可接受的。根据我们的结果,每次测试设置的1〜(ST)的%R&R为边际度为16.2%,每次测试设置的2〜(ND)为8.9%,为验收。因此,提供更好的可重复性和再现性,每个测试设置具有在恒定的75℃下在热棒周围盘绕的PMF,选择了6厘米直径,下一步研究了热温度的影响LC / UPC PMF连接器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号