摘要

Zinc oxide surge arrester with gap has been widely used in transmission lines. There is no effective method to detect the performance degradation of the current, because of its normal operation without divulge current. This paper presents an experiment about the characteristics of lightning impulse aging and the surface temperature increment of the zinc oxide arrester (MOA) by test. According to this experiment, a method for monitoring the state of zinc oxide arrester with gap is proposed. In this method, the large current impact times and the surface temperature increment as the state quantity. And the on-line monitoring device for zinc oxide arrester with gap was developed correspondingly. The test results show the effectiveness of the method.
机译:具有间隙的氧化锌电涌放电器已被广泛用于传输线。由于电流正常运行而没有泄漏电流,因此没有有效的方法来检测电流的性能下降。本文通过试验对雷电冲击老化的特性和氧化锌避雷器(MOA)的表面温度升高进行了实验。根据该实验,提出了一种监测带间隙氧化锌避雷器状态的方法。在这种方法中,大的电流冲击时间和表面温度作为状态量增加。并相应开发了带间隙的氧化锌避雷器在线监测装置。测试结果表明了该方法的有效性。