首页> 外文会议>International Universities Power Engineering Conference >Insulation fault detection and localisation in electric and hybrid electric vehicles
【24h】

Insulation fault detection and localisation in electric and hybrid electric vehicles

机译:电动和混合动力汽车的绝缘故障检测和定位

获取原文

摘要

This paper discusses a method for detection and localisation of the insulation faults in electrical equipment distributed along the body of electric and hybrid electric vehicles. At the beginning of the fault detection procedure it is required that the vehicle powertrain be shut-down. The method is based on measurement and comparison of leakage currents in every device in the electrical powertrain. The leakage currents are generated by a high voltage signal generator connected between the vehicle body ground and dc-bus wires and shifting the potential between the electrical equipment and chassis. The currents are measured using a current clamp to detect the active component of the leakage current corresponding to an insulation fault. The proposed method was implemented in a prototype device used to detect an insulation fault in subway powertrains (i.e. a metro train). The method demonstrated excellent efficiency through successful detection and localisation of insulation faults.
机译:本文讨论了一种用于检测和定位沿电动和混合动力电动汽车车身分布的电气设备中绝缘故障的方法。在故障检测过程开始时,需要关闭车辆动力总成。该方法基于电力传动系中每个设备中泄漏电流的测量和比较。泄漏电流由连接在车身接地和直流母线之间的高压信号发生器产生,并在电气设备和底盘之间转移电势。使用电流钳测量电流,以检测与绝缘故障相对应的泄漏电流的有效分量。所提出的方法在用于检测地铁动力总成(即地铁)中的绝缘故障的原型设备中实现。通过成功检测和定位绝缘故障,该方法证明了出色的效率。