Diffusion MRI offers the ability to noninvasively characterize the microstructure of myocardium tissue and detect disease related pathology in cardiovascular examination. This study investigates the feasibility of in vivo cardiac diffusion MRI under free-breathing condition. A high-speed imaging technique, correlation imaging, is used to enable single-shot turbo spin echo for free-breathing cardiac data acquisition. The obtained in vivo cardiac diffusion-weighted images illustrate robust image quality and minor geometry distortions. The resultant diffusion scalar maps show reliable quantitative values consistent with those previously published in the literature. It is demonstrated that this technique has the potential for in vivo free-breathing cardiac diffusion MRI.
机译:扩散MRI提供了无创地表征心肌组织的微结构并检测心血管检查中与疾病相关的病理的能力。这项研究调查了在自由呼吸条件下体内心脏扩散MRI的可行性。高速成像技术(相关成像)用于启用单脉冲涡轮自旋回波,以进行自由呼吸的心脏数据采集。所获得的体内心脏扩散加权图像说明了稳健的图像质量和较小的几何畸变。所得的扩散标量图显示了可靠的定量值,与先前在文献中发表的值一致。证明了该技术具有体内自由呼吸心脏扩散MRI的潜力。