首页> 外文会议>International Conference on Electrical Machines >A method for calculating equivalent circuit constants of a synchronous generator with damper using a DC decay test with open and shorted field windings
【24h】

A method for calculating equivalent circuit constants of a synchronous generator with damper using a DC decay test with open and shorted field windings

机译:使用DC衰减测试使用DC衰减测试使用DC衰减测试计算同步发电机的等效电路常数用打开和短路场绕组

获取原文

摘要

The authors describe a method for calculating equivalent circuit constants of synchronous generators using open and shorted operational impedances obtained by the DC decay tests. In the proposed method, it is possible to find all constants only by a stationary test, including the armature leakage reactance. This method makes it possible to improve transient analysis accuracy on not only the armature side current but also the field side. Especially the issue of field current error can be resolved. The validity of the proposed method is demonstrated by a sudden three-phase short-circuit test on a salient laminated pole machine of 10 kVA-200 V-31.9 A-4 P-50 Hz.
机译:作者描述了一种使用DC衰减测试获得的开放和短路操作阻抗计算同步发电机的等效电路常数的方法。在所提出的方法中,可以仅通过静止测试找到所有常数,包括电枢漏电抗。该方法使得可以提高瞬态分析精度,不仅是电枢侧电流,而且可以改善磁侧电流,也可以提高磁场侧。特别是可以解决现场当前错误的问题。通过10kVA-200V-31.9A-4P-50Hz的突出层压杆机上突出的三相短路试验证明了所提出的方法的有效性。