摘要

Recently, many energy-aware routing algorithms are proposed to decrease the energy consumption of data center network. However, these methods ignore the effect of working time on energy consumption. In this paper, we analyze the energy consumption model and propose an energy-aware routing algorithm by jointly considering power consumption and working time. According to the simulation results, the flow driven energy-aware routing algorithm saves nearly 50 percent of energy compared with flow preemption energy-aware routing algorithm when transmission rate is limited by the available bandwidth, while it saves about 58.3 percent of energy compared with flow aggregation energy-aware routing algorithm when the transmission rate is limited by the forwarding rate of server's NIC.
机译:近年来,提出了许多节能的路由算法来减少数据中心网络的能耗。但是,这些方法忽略了工作时间对能耗的影响。在本文中,我们分析了能耗模型,并结合能耗和工作时间提出了一种节能路由算法。根据仿真结果,在可用带宽限制传输速率的情况下,流驱动的节能路由算法与抢占式节能路由算法相比节省了近50%的能量,而与流量相比,节能了约58.3%当传输速率受服务器NIC的转发速率限制时,采用聚合能量感知路由算法。