首页> 外文会议>International Conference on AC and DC Power Transmission >Network topology of urban grid considering N-1-1 criterion
【24h】

Network topology of urban grid considering N-1-1 criterion

机译:考虑N-1-1准则的城市电网网络拓扑

获取原文

摘要

Urban area is the major load centre of power system. To meet N-1-1 criterion is important for an urban grid with the requirement of high power supply reliability. The considerations of N-1-1 criterion in overseas developed areas are compared in this paper. The impact of the configuration of substations and the inter-connections on power supply reliability is analysed for the grid under N-1-1 condition. In addition, the urban network topology which can meet the N-1-1 criterion of British ER P2/6 guideline is discussed. A more stringent N-1-1 criterion and corresponding network topology is proposed to accommodate the development of urban grid.
机译:市区是电力系统的主要负荷中心。对于具有高供电可靠性要求的城市电网,满足N-1-1标准非常重要。比较了国外发达地区对N-1-1标准的考虑。分析了在N-1-1条件下电网的变电站和互连的配置对供电可靠性的影响。此外,讨论了可以满足英国ER P2 / 6准则的N-1-1标准的城市网络拓扑。为了适应城市电网的发展,提出了更严格的N-1-1准则和相应的网络拓扑。