首页> 外文会议>International Conference on Mechanical and Aerospace Engineering >Study on Damage of a Floating Roof-type Oil Storage Tank due to Thermal Stress
【24h】

Study on Damage of a Floating Roof-type Oil Storage Tank due to Thermal Stress

机译:浮屋顶型储油罐损坏引起的热应力损伤研究

获取原文

摘要

Several cracks were found on some actual floating roofs of a crude oil tank in the oil refinery located in southern Japan. We assumed that one of reasons would be due to thermal stress caused by temperature changes during the day. In order to consider whether the thermal stress could the cause damages on the floating roof, strain and temperature were measured on the actual floating roof by using optical fiber gauges. Furthermore, thermal stress analysis was carried out as effective analysis.