首页> 外文会议>IEEE International Power Electronics and Motion Control Conference >Simulation of Fault Operation of a 13-level CHB Multilevel Converter for Power Coolant Pump
【24h】

Simulation of Fault Operation of a 13-level CHB Multilevel Converter for Power Coolant Pump

机译:13级CHB多级转换器电动冷却液泵故障运行仿真

获取原文

摘要

This paper discusses the simulation of the cascaded H-bridge (CHB) multilevel converter for power coolant pump with the demand of high reliability and robustness. Multi-level converters are designed to control medium-voltage motors, energy conversion, active power filtering, and many other applications. First, an overview of the CHB converter, the method of control, and operation under fault conditions is described. The next part deals with the requirements of the application of the converter and the parameters of the simulation system. Then the 13-level multilevel converter is simulated during operation under normal conditions and during operation under abnormal conditions. If the cell is damage, it is bypassed by an auxiliary switch. The simulated voltages and torques were compared with each other. As a result, the converter is able to operate even with three faulty cells without interrupting the operation of the cooling pump.
机译:本文讨论了级联H桥(CHB)多级转换器的电动冷却液泵的模拟,具有高可靠性和鲁棒性的需求。 多级转换器设计用于控制中电动机,能量转换,有源电力滤波等许多应用。 首先,描述了CHB转换器,控制方法和故障条件下的操作概述。 下一部分涉及转换器应用的要求和仿真系统的参数。 然后在正常条件下操作期间和在异常条件下运行期间模拟13级多电平转换器。 如果单元格损坏,则由辅助开关旁路。 彼此比较模拟电压和扭矩。 结果,转换器即使在不中断冷却泵的操作的情况下也能够操作三个故障的电池。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号