Characterization of a High Temporal Resolution TDLAS System for Measurements in a Shock Tube Facility

机译:冲击管设施中用于测量的高时间分辨率TDLAS系统的特性

获取原文
获取外文期刊封面目录资料

摘要

This paper presents successful measurements of post shock temperature in a shock tube facility. The measured temperature behind the incident and reflected shock wave compares well with the prediction of a 1-dimensional, inviscid calculation. Scan frequencies of 10,50 and 100 kHz were used and the effect on the measurement accuracy is discussed. The maximal deviation from the calculation is within 2.5%. The standard deviation calculated for six measurements was approximately constant for all investigations and within the same order as the uncertanties introduced by the test facility and the data processing. The upper limit of the scan frequency is limited by the bandwidth limitation of the photo reciever used.
机译:本文介绍了在激波管设施中成功测量激波后温度的方法。入射声波和反射冲击波后的测得温度与一维无粘性计算的预测值很好地比较。使用了10,50和100 kHz的扫描频率,并讨论了对测量精度的影响。与计算的最大偏差在2.5%以内。对于所有调查,针对六次测量计算出的标准偏差均大致恒定,并且处于与测试设备和数据处理所引入的不确定性相同的顺序内。扫描频率的上限受所用光接收器的带宽限制的限制。