Out of step with the rapid growth of China's electricity load demand, the infrastructure of power grid in many areas is not strong enough to insure the security of power system operation. In this case, considering the strict N-1 conditions of lines and transformers, the situation that there is no feasible solution for the security-constrained unit commitment (SCUC) might occasionally occur. In order to address this issue, a homogenized-overload model based on SCUC is proposed in this paper. The homogenized-overload model could obtain a reasonable, suboptimal solution reducing the security risks by lowering the average overload level and reducing the number of overload lines without sacrificing the economy of unit commitment. To identify the overload line set, an identifying method based on the Benders decomposition algorithm is also proposed. The homogenized-overload model and the identifying method are tested respectively in a 6-bus system case and a real provincial power system in China. Simulation results show the validity of the model and the method.
机译:随着中国电力需求的快速增长,许多地区的电网基础设施不足以确保电力系统运行的安全性。在这种情况下,考虑到严格的N-1线路和变压器条件,可能偶尔会出现安全约束单位承诺(SCUC)没有可行解决方案的情况。为了解决这个问题,本文提出了一种基于SCUC的均质化过载模型。均质化的过载模型可以通过降低平均过载水平和减少过载线路的数量而获得一个合理的,次优的解决方案,从而降低安全风险,而又不牺牲单位承担的经济性。为了识别过载线,提出了一种基于Benders分解算法的识别方法。分别在6总线系统案例和中国实际省级电力系统中测试了均质化过载模型和识别方法。仿真结果表明了该模型和方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号