In this paper we consider sensor networks for detecting contamination in urban water distribution systems. We assume that the sensor nodes are installed at connection points only (through the manholes) and are driven by supercapacitors charged by water flow. Although water systems may be affected by a large variety of contaminants, only a few sensors can be practically deployed. Thus many types of contaminants are sensed via "proxy sensing", which may not be 100% reliable. In this paper we consider such a situation and examine the problem of collaborative adaptation of heterogeneous set of sensors in order to maximize contamination detection, especially during periods of almost zero natural water flow. The paper shows, through extensive simulations, that the proposed approach can drastically reduce the contamination reporting time from 3.5 hours to ∼6 minutes, compared to the case without adaptation.
机译:在本文中,我们考虑了用于检测城市供水系统中污染的传感器网络。我们假设传感器节点仅安装在连接点处(通过人孔),并且由水流充电的超级电容器驱动。尽管水系统可能会受到各种各样的污染物的影响,但实际上只能部署几个传感器。因此,许多类型的污染物是通过“代理感测”来感测的,这可能不是100%可靠的。在本文中,我们考虑了这种情况,并研究了异构传感器组的协作适应问题,以最大程度地提高污染物检测的效率,尤其是在自然水流量几乎为零的时期。本文通过广泛的模拟显示,与没有适应措施的情况相比,该方法可以将污染报告时间从3.5小时大幅减少至6分钟左右。