摘要

Existing techniques exploiting local measurements to calculate the long-term voltage stability mostly rely on Thevenin equivalent concept. This notion calls for two or more distinct measurement sets for computation of Thevenin parameters assuming that the power system stays unchanged during the data collection, which is not essentially true. This paper presents a new method for computation of voltage stability margin associated with system load buses using voltage and current magnitudes. The proposed method is independent from the system variations; thus, it does not suffer from the shortcoming of regular Thevenin equivalent method. The new methodology is based on this observation that in the stable region of voltage stability curve, the normalized absolute value of the rate of change of voltage magnitude is greater than that of the current magnitude. This observation is supported by the theoretical analysis as well. To demonstrate performance of the developed method, a simple radial network and the IEEE 14-bus test system are examined.
机译:现有的利用局部测量来计算长期电压稳定性的技术主要依靠戴维南等效概念。假设电力系统在数据收集过程中保持不变,此概念需要两个或更多个不同的测量集来计算戴维南参数。本文提出了一种使用电压和电流幅度来计算与系统负载母线相关的电压稳定裕度的新方法。所提出的方法与系统的变化无关。因此,它没有常规的戴维宁等效法的缺点。新方法基于此观察结果,即在电压稳定曲线的稳定区域中,电压幅值变化率的归一化绝对值大于电流幅值的归一化绝对值。该观察结果也得到理论分析的支持。为了演示所开发方法的性能,我们研究了一个简单的径向网络和IEEE 14总线测试系统。