THE FIRST TWO OCCURRENCES OF EXTERNAL DAMAGE ON 600TT ALLOY TUBES IN FRANCE

机译:法国600TT合金管的第二次外部损坏

获取原文

摘要

During the last decade, in different countries, several occurrences of external corrosion have been identified on SG tube bundles with thermally treated 600 alloy tubes. In France, this feedback has led EDF to enhance the SG inspection program. Nevertheless, until now, no damage of this type had been reported. Recently, during in-service inspection on an SG with 600TT alloy tubes, eddy current tests have highlighted a signal that could be related to external corrosion. The tube was removed and sent to the EDF hot laboratory for destructive examinations. Various examinations were performed at different scales to characterize the causes of the NDT signal, the material properties, the environmental parameters and the residual stresses. This paper describes these examinations, their results, and our analysis of the mechanism and the potential aggravating factors. We can then compare our conclusions with similar known cases.
机译:在过去的十年中,在不同的国家中,已发现在经过热处理的600合金管的SG管束上发生了几次外部腐蚀。在法国,这种反馈使EDF加强了SG检查计划。但是,到目前为止,还没有这种类型的损坏的报道。最近,在对带有600TT合金管的SG进行服务期间的检查中,涡流测试突出了一个信号,该信号可能与外部腐蚀有关。取出试管,并送至EDF热实验室进行破坏性检查。在不同的尺度上进行了各种检查,以表征NDT信号的原因,材料特性,环境参数和残余应力。本文介绍了这些检查,它们的结果,以及我们对机理和潜在加重因素的分析。然后,我们可以将我们的结论与类似的已知案例进行比较。