Several lidar campaigns have been performed in support of calibration/validation of DMSP SSM/T-2 microwave water vapor sensors. Calibration capabilities were demonstrated by performing radiative transfer calculations based on water vapor profiles measured by lidar. The calculations agreed with collocated SSM/T-2 atmospheric channel measurements to better than 1K RMS, whereas discrepancies were frequently greater than 2 K for radiative transfer based on conventional AIR and Vaisala radiosonde profiles. The improved capability is attributed to the new ability to measure water vapor from 8 to 14 km altitude. Conventional radiosondes tend to be unresponsive to water vapor at the low temperatures typical of altitudes above 8 km.
机译:已经在支持DMSP SSM / T-2微波水蒸气传感器的校准/验证的支持下进行了几个LIDAR运动。通过基于LIDAR测量的水蒸气分布进行辐射转移计算来证明校准能力。根据常规空气和vaisala无线电探测器谱差异,与合并的SSM / T-2大气通道测量值达到优于1K rms的差异,而差异大于2k,差异大于2 k,而散热转移。改善的能力归因于测量8至14公里高度的水蒸气的新能力。常规的无线电体往往对水蒸气倾向于在8km以上的高度典型的低温下的水蒸气。