The SERF atomic spin magnetometer, which can be used to measure the residual weak magnetic field in the magnetic shield due to its ultrahigh sensitivity, is elaborated in this paper. The method of using the SERF atomic spin magnetometer to measure the residual weak magnetic field in the magnetic shield was presented. The compensating coils, which were placed inside the magnetic shield, produced the uniform magnetic fields along the x, y and z directions, and they were reverse direction with the residual weak magnetic fields; via the cross modulation method, the residual weak magnetic fields could be counteracted. At this time, the magnetic fields producing by the compensating coils were equal to the residual weak magnetic fields in the magnetic shield. The experimental results showed that the residual weak magnetic fields were approximate 0.5 nT, 1.0 nT and 7.0 nT along the x, y and z directions, respectively; and the maximum measurement errors were approximate 0.0169, 0.0377, and 0.5071 along the x, y and z directions, respectively. Finally, the reasons of measurement error were analyzed.
机译:阐述了SERF原子自旋磁强计,由于其超高的灵敏度,可用于测量磁屏蔽中的残留弱磁场。提出了利用SERF原子自旋磁力仪测量磁屏蔽罩内残余弱磁场的方法。放置在磁屏蔽罩内部的补偿线圈沿x,y和z方向产生均匀的磁场,而它们在相反的方向上具有残留的弱磁场。通过交叉调制方法,可以抵消残留的弱磁场。此时,补偿线圈产生的磁场等于磁屏蔽罩中的残留弱磁场。实验结果表明,沿x,y和z方向的残余弱磁场分别约为0.5 nT,1.0 nT和7.0 nT。沿x,y和z方向的最大测量误差分别约为0.0169、0.0377和0.5071。最后,分析了测量误差的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号