A Comparative Study Between Jordanian Overall Heat Transfer Coefficient (U-Value) and International Building Codes

机译:约旦整体传热系数(U价值)和国际建筑规范的比较研究

获取原文

摘要

Depletion of fossil fuel and the environmental effect associated with the use of it have made the topic of "thermal insulation regulations" a major concern in Jordan and worldwide. This paper reviews the overall heat transfer coefficient U-value in Jordanian code for the building envelope, which represents how much the building envelope transfer heat to the outside environment. U-value was reviewed with respect to the following factors, heating degree-days, the heating load required to achieve thermal comfort. Based on the review a new U-value of 0.65 W/m2.K was proposed and it was found that this value reduces the energy demand by half.
机译:化石燃料的消耗和与利用相关的环境效果使“保温规则”主题成为约旦和全球的主要问题。本文审查了建筑信封的约旦代码中的总传热系数U值,这代表了建筑物包络将热量传递到外部环境。根据以下因素,加热程度,加热载荷来审查U值,所需的热舒适度。基于审查新的U值为0.65 w / m 2 .K是提出的,发现该价值将能源需求降低了一半。