IEC60034 is the standard for rotating electrical machines. IEC60034-5 defines ingress protection (IP) class of the machine and IEC60034-6 discuss mainly cooling methodology. A test has been performed on a wind turbine with squirrel cage induction generator of IP54 class. Cooling configuration was changed from IC6A1A6 (totally enclosed air to air cooled) configuration to IC3A1 (open ventilated). Paper presents some electrical and mechanical challenges associated with environmental conditions. Well protected duct and filter housing were used during testing. IC3A1 cooling bring certain advantages for the generator used in wind turbine application. This paper focuses on the need of proper filter housing selection to secure IC3A1 generator. Tradeoff between IP class, required performance, cost, serviceability of the machine are important factors and addressed in the paper. Recommendation has been made for a proper filtration selection to secure generator with good IP class. Recommendation is based on a test performed on a wind turbine.
机译:IEC60034是旋转电机的标准。 IEC60034-5定义了机器的入口保护(IP)类,IEC60034-6主要讨论了冷却方法。在具有IP54级的鼠柱笼式诱导发电机的风力涡轮机上进行了测试。冷却配置从IC6A1A6(完全封闭的空气到空气冷却)配置改变为IC3A1(打开通气)。论文呈现出与环境条件相关的一些电气和机械挑战。在测试期间使用良好保护的管道和过滤器外壳。 IC3A1冷却为风力涡轮机应用中使用的发电机带来了某些优点。本文侧重于需要适当的过滤器外壳选择来保护IC3A1发电机。 IP类之间的权衡,所需的性能,成本,机器的可维护性是重要因素,并在论文中解决。建议采用适当的过滤选择,以保护具有良好IP类的生成器。推荐基于在风力涡轮机上进行的测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号