首页> 外文会议>IEEE Portuguese Meeting in Bioengineering >Population-based dosimetry in nuclear medicine and pet: Development of Portuguese female and male anthropomorphic models
【24h】

Population-based dosimetry in nuclear medicine and pet: Development of Portuguese female and male anthropomorphic models

机译:核医学与宠物的基于人口的剂量测定:葡萄牙女性和男性拟人模型的发展

获取原文

摘要

Summary form only given. Internal organ dose estimates have always depended on standard reference models that mimic the interior and exterior anatomical features of the human body. These models are based on 20-30 year-old and healthy average European and North American populations, their organ masses and body weights and heights corresponding to the 50th percentile data [1]. However, if an individual patient deviates greatly from the reference anatomy, the use of a standard phantom can hinder the precision of the dose assessment being performed. Published anthropometric studies [2] suggest that the Portuguese population deviates from the parameters defined for the reference dosimetric models [3]. The general aim of the present research is to develop and validate two new anthropomorphic models of the human body (one male and one female), that specifically represent Portuguese adult patients who undergo PET/CT examinations. A secondary goal of this project is to profile the Portuguese patients undergoing PET/CT examinations, in respect to their age and internal and external anatomical features. In order to achieve this goal, anthropometric patient data regarding F-FDG PET/CT examinations performed at the Institute of Nuclear Sciences Applied to Health (ICNAS) were collected and analyzed. Statistical hypothesis tests (sign-tests) confirmed that the Portuguese adult patient population anatomy deviates greatly from that of the reference anthropometric phantoms most commonly used in internal dosimetry, at least where age, weight and height are concerned. This supports recent approaches in Internal Radiation Dosimetry, which challenge the “Reference Man paradigm”, that is, the application of reference computational phantoms to the overall population [1]. New anthropomorphic models of the human body, representing Portuguese adult patients who undergo PET/CT examinations, will be created by combining Monte Carlo simulation of the radiation trans- ort and image quantification techniques. These models will facilitate an accurate estimation of internal radiation doses.
机译:摘要表格仅给出。内部器官剂量估计总是依赖于标准参考模型,模仿人体的内部和外部解剖特征。这些型号基于20-30岁和健康的欧洲和北美人口,他们的器官群体和体重和对应于第50百分位数的身高和高度[1]。然而,如果个体患者从参考解剖学偏离大大偏离,则使用标准幻像可以阻碍所进行的剂量评估的精度。出版的人体测量研究[2]表明葡萄牙人群体偏离为参考剂量测定模型定义的参数[3]。本研究的一般目标是开发和验证人体(一名男性和一名雌性)的两个新的拟人模型,具体代表经过宠物/ CT检查的葡萄牙成年患者。该项目的次要目标是在其年龄和内部解剖功能方面介绍宠物/ CT考试的葡萄牙患者。为了实现这一目标,收集并分析了对应用于健康(ICNA)的核科学研究所进行的F-FDG PET / CT检查的人类测量患者数据。统计假设试验(标志测试)证实,葡萄牙成年患者群体解剖学从内部剂量中最常使用的参考人体测量幽灵的偏离,至少在涉及年龄,重量和高度。这支持最近在内部辐射剂量测定中的最近方法,这挑战了“参考人范例”,即,将参考计算幻影应用于整体人群[1]。将通过组合辐射转换器和图像量化技术的蒙特卡罗模拟来创建人体的新人体的人体拟人体模型,以辐射传输和图像量化技术相结合来创建葡萄牙成年患者。这些模型将促进内部辐射剂量的准确估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号