首页> 外文会议>International astronautical congress >THE LABORATORY CALIBRATION OF A NOVEL SURFACE POTENTIAL MONITOR AT GEO
【24h】

THE LABORATORY CALIBRATION OF A NOVEL SURFACE POTENTIAL MONITOR AT GEO

机译:GEO新型表面电位监测器的实验室标定

获取原文

摘要

A novel surface potential monitor (SPM) has been developed for a satellite at GEO in China. The SPM consisted of a surface charge detector head, an electrostatic voltmeter and associated control electronics. This novel SPM has been calibrated in a simulated space environment in our laboratory. This paper describes the calibration system which consists of a non-contact voltmeter and an electron beam current monitor. The calibration method is also given, with which the linearity error of SPM is proved less than 1.7.
机译:在中国的GEO卫星上已经开发了一种新型的表面电势监测器(SPM)。 SPM包括一个表面电荷检测器头,一个静电电压表和相关的控制电子装置。这款新颖的SPM已在我们实验室的模拟太空环境中进行了校准。本文介绍了由非接触式电压表和电子束电流监控器组成的校准系统。还给出了校准方法,用该方法可以证明SPM的线性误差小于1.7。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号