Historically restoration switching strategies have been deployed to improve the system reliability by addressing effects resulting from permanent fault activity via distribution automation schemes. This paper investigates the potential role of a Distribution Automation System (DAS) in dealing with nuisance tripping where customers are often disturbed by frequently occurring short-term supply outages affecting their quality of supply. In order to mitigate these nuisance supply interruptions, this paper will focus on the development of an integrated decision support system that utilises available Supervisory Control And Data Acquisition (SCADA) alarm data and distribution network data available from pole mounted auto-reclosers (provided by a distribution network operator) to detect and diagnose pre-permanent fault activity responsible for nuisance tripping. The developed system will detect the advent of nuisance tripping on a circuit, and subsequently conduct prognostic health checks to determine the cause of the underlying circuit fault activity, responsible for the nuisance tripping, which often leads to more serious permanent faults in the future. Previous fault activity could be used to identify fault signature data patterns and trends through data mining techniques that predict potential nuisance tripping associated with network behaviour, transient activity and permanent network faults. The distribution automation scheme may be subsequently operated to mitigate the risk of nuisance tripping and so improve the level of customer service associated with network operators. This system is capable of providing ‘early warning’ of evolving faults which in turn allows an intervention to take place to inform and assist maintenance staff to take appropriate preventative action to minimise negative effect prior to it occurring.
机译:已经部署了历史恢复切换策略,以通过通过分销自动化方案寻址永久性故障活动产生的效果来提高系统可靠性。本文调查了分销自动化系统(DAS)在处理滋扰绊倒时潜在的作用,其中客户经常受到影响其供应质量的经常发生的短期供应缓解。为了减轻这些滋扰供应中断,本文将专注于开发综合决策支持系统,该系统利用可用的监督控制和数据采集(SCADA)报警数据和分销网络数据可从杆安装的自动重电器(由A提供)分发网络运营商)检测和诊断负责滋扰绊倒的永久性故障活动。开发系统将检测电路上滋扰绊倒的出现,随后进行预后的健康检查,以确定潜在的电路故障活动的原因,负责滋扰绊倒,这通常会导致未来更严重的永久性故障。之前的故障活动可用于通过数据挖掘技术来识别故障签名数据模式和趋势,这些技术预测与网络行为,瞬态活动和永久网络故障相关联的潜在滋扰跳闸。随后可以操作分发自动化方案以减轻滋扰跳闸的风险,因此提高与网络运营商相关联的客户服务水平。该系统能够提供不断变化的故障的“预警”,这反过来又允许进行干预以提供通知和协助维护人员采取适当的预防措施,以最小化发生之前的负面影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号