摘要

Accurate understanding of inverter performance in the field is essential for energy estimation of PV power plants. The self-reported field efficiencies of six utility-scale inverter models from four different manufacturers were studied. In total, 355 inverters were included in this analysis. Efficiency curves were calculated from AC and DC inverter measurements and compared to manufacturer and CEC efficiency curves, when available. Despite a large statistical sample, the expected and measured mean efficiencies differed by −4.1% to +1.5%. This suggests either a systematic sensor/measurement processing algorithm issue or a misunderstanding of field inverter efficiency as opposed to efficiency characterization in the lab. Careful field analysis and characterization of inverter-reported data appear to be the only methods to truly resolve this discrepancy.
机译:对现场逆变器性能的准确了解对于光伏电站的能源估算至关重要。研究了来自四个不同制造商的六个实用规模的逆变器模型的自报告场效率。该分析总共包括355个逆变器。根据交流和直流逆变器的测量结果计算出效率曲线,并与制造商和CEC效率曲线(如果有)进行比较。尽管有大量的统计样本,但预期和测得的平均效率相差-4.1%至+ 1.5%。这暗示了系统的传感器/测量处理算法问题或对现场逆变器效率的误解,而不是实验室中的效率表征。认真地对变频器报告的数据进行现场分析和表征似乎是真正解决这一差异的唯一方法。